ALAN's Electrosurgical Unit (Diathermy) is designed with latest miniature electronic circuit design technology. The advanced microcontroller based helps in achieving the desired tissue effects. It is small in size but Surprises on Performance.


SAFETY :
  •  Unit can work with input voltage of 230 VAC.
  •  High Frequency Leakage monitoring and controlling system.
  •  Equipotential port for ground connection.
  •  Built-in-line filter protects from voltage surges/bad line conditions.
  •  Cardiac floating output unit.
  •  Convection cooling system offers better unit's life.
  •  Handswitch and Footswitch short detection during self-test.
RELIABILITY :
  •  Power up Self-Test to ensure unit healthiness.
  •  Multiple microcontroller supervision for RF power accuracy.
  •  Audio and Visual indication for easy interpretation.
  •  Different audible tones for activation, warning etc.
  •   Light indication for split or non-split patient plate connection.
  •   User settable maximum RF activation Timeout limit.

GENERAL FEATURES :
  •   Maximum output of 300 Watts
  •  Monopolar outputs can be activated via Hand switch and Foot switch.
  •  Monopolar output can be activated via handswitch & footswitch.
  •  Simultaneous coagulation facility in Monopolar.
  •  Low Cut mode for reduced smoke in Laparoscopy & Open Surgeries.
  •  Simultaneous coagulation for 2 surgeons by footswitch / handswitch combination.
  •  The unit has 3pedal foot switch, explosion proof / water proof Foot Switch.
  •  Blend mode for cutting with haemostasis effect in special surgical applications.
  •  Desiccate mode for standard coagulation in Monopolar.
  •  Restores previous activated power setting during Power Up/Restart.
  •  Digital volume control and audio-visual indications for all outputs
  •  Light indication for split or non-split patient plate connection.
  •  Light indication for patient contact quality with return electrode.
  •  Built-in patient plate contact quality monitoring system for patient's safety.
  •  PPCM deactivates output power if it senses improper contact between patient & return electrode to eliminate the risk of patient burn.
  •  Unit is compatible with Single, Double & Three Pedal Footswitch.



INPUT SUPPLY :

Input Supply : 230VAC +/- 20% 50 Hz

Loading Duty Factor : 10Sec (Active) / 30 Sec (Pause)

Output Control : Digital Display, Push Buttons in all Modes.

SAFETY STANDARD :

Basic Construction : Accordance with
IEC 60601 - 1,
IEC 60601 - 1 - 2 &
IEC 60601 - 2 - 2

Protection Class : 1

Unit Type : CF

All Output : Floating Output

Electrical Potential : Connecting Pin and Balancing Indicated by Symbol.